The HE 200 A and HE 200 B Beam Series at a Glance
HEA200 and HEB200 are two hot rolled wide flange sections that share the same nominal 200 mm depth class but differ substantially in the amount of steel in the cross section. Designers meet them constantly on industrial and commercial work, and the choice between them usually comes down to load, span and the weight that the frame can carry. Understanding where the two profiles diverge, in web thickness, flange thickness and mass, makes the selection straightforward.
Both sections are ordered to the European dimensional standard for hot rolled H and I sections, and both are available in the usual structural steel grades used for buildings and bridges.
Section Dimensions of HEA200 and HEB200
In the standard size notation h x b x tw x tf, the two profiles are written as follows. Note that the flange width is the same, 200 mm, for both sections; the real difference lies in the web and flange thickness and in the height of the section.
| Property | HEA200 | HEB200 |
|---|---|---|
| Series type | Narrow flange HE series | Wide flange HE series |
| Overall height h | 190 mm | 200 mm |
| Flange width b | 200 mm | 200 mm |
| Web thickness tw | 6.5 mm | 9 mm |
| Flange thickness tf | 10 mm | 15 mm |
| Nominal mass | about 42.3 kg/m | about 61.3 kg/m |
Expressed as differences, the HEB200 section has a web that is roughly 38 percent thicker and a flange that is 50 percent thicker than the HEA200 profile, and it weighs about 45 percent more per metre. Those three figures explain almost every practical difference discussed below.
Bearing Capacity and Stiffness
Because the flange and web of HEB200 are thicker, the section has a larger cross sectional area and a larger second moment of area about the strong axis. The practical consequences are:
Higher bending resistance, so the section can carry a greater bending moment at the same stress level.
Lower deflection at a given span and load, which matters on long spans and on floors with tight serviceability limits.
Greater resistance to local buckling of the flange and web, because both plates are thicker.
Higher axial capacity for use as a column or as a chord in a braced frame.
HEA200 remains an efficient section where the structure is governed by stiffness rather than strength, or where the self weight of the frame is a significant part of the total load.
Bending and Torsion Behaviour
The thicker flange of HEB200 increases the out of plane stiffness of the section, so it resists lateral torsional buckling and torsion better than HEA200. Where a beam supports a load applied below the shear centre, or where the compression flange is not restrained at close centres, that additional stiffness is valuable. HEA200 can still be used in such positions when the compression flange is restrained by a concrete slab, a deck or a system of secondary beams.
Typical Application Scenarios
HEA200: general building frames, light industrial structures, purlins and secondary beams, platforms and supports where weight must be kept low and loads are moderate.
HEB200: main beams of large industrial buildings, frame beams of high rise construction, bridge supporting structures, machinery bases and heavily loaded columns.
In many projects the two profiles appear together: HEB200 is used for the primary members that carry the largest moments, while HEA200 is used for the secondary members where a lighter section is sufficient.
Selection and Ordering Checklist
Confirm the governing load combination and whether strength, deflection or vibration controls the design.
Check the available headroom, because the two sections are not the same height and the connection details differ.
Verify the steel grade required for the temperature and toughness demands of the project.
State the section designation, grade, length, cutting tolerance and surface condition on the enquiry.
Allow for the mass difference in transport and erection planning; the heavier profile needs adequate lifting capacity.
Frequently Asked Questions
Q: Is HEB200 stronger than HEA200?
Yes. HEB200 has a thicker web and flange, so it provides higher bending, axial and torsional resistance than HEA200 of the same nominal depth class.
Q: Are the two sections interchangeable?
Not directly. The overall height and the thicknesses differ, so connection plates, bolt positions and clearances have to be checked before one profile is substituted for the other.
Q: Which profile is lighter?
HEA200 is lighter, at about 42.3 kg per metre against about 61.3 kg per metre for HEB200, which makes it the economical choice when stiffness is not critical.
Q: When should HEB200 be preferred?
Use HEB200 where the member carries heavy loads, spans a long distance, acts as a column, or needs extra resistance against torsion and lateral torsional buckling.
Q: Do both sections have the same flange width?
Yes. Both have a nominal flange width of 200 mm, so the difference is in the web thickness, the flange thickness and the section height.