1. European Standard HEA 150 (H-Beam)
| Parameter | Value |
|---|---|
| Height (h) | 150 mm |
| Width (b) | 150 mm |
| Web Thickness (tw) | 6 mm |
| Flange Thickness (tf) | 9 mm |
| Section Area (A) | 31.4 cm² |
| Weight per Meter | 24.7 kg/m |
| Moment of Inertia (Ix) | 1,040 cm⁴ |
Common Uses: Light to medium structural frames, support beams.
2. European Standard HEB 150 (Wider Flange)
| Parameter | Value |
|---|---|
| Height (h) | 150 mm |
| Width (b) | 150 mm |
| Web Thickness (tw) | 8 mm |
| Flange Thickness (tf) | 12 mm |
| Section Area (A) | 42.7 cm² |
| Weight per Meter | 33.6 kg/m |
| Moment of Inertia (Ix) | 1,510 cm⁴ |
Common Uses: Heavier load-bearing columns, industrial structures.
3. Chinese Standard HN 150 (Narrow Flange)
| Parameter | Value |
|---|---|
| Height (h) | 150 mm |
| Width (b) | 75 mm |
| Web Thickness (tw) | 5 mm |
| Flange Thickness (tf) | 7 mm |
| Weight per Meter | 16.9 kg/m |
Common Uses: Secondary beams, lightweight frameworks.
H Beam 150 vs. I Beam 150 Comparison
| Feature | H Beam 150 (HEA/HEB) | I Beam 150 (IPE) |
|---|---|---|
| Flange Width | Wider (150mm) | Narrower (75mm) |
| Weight | Heavier (24–34 kg/m) | Lighter (~15 kg/m) |
| Bending Strength | Higher (1,040–1,510 cm⁴) | Lower (~850 cm⁴) |
| Best For | Columns, heavy beams | Light roof structures |
FAQ
1. What does "150" mean in H beam 150?
It refers to the depth (height) of the beam (150mm).
2. Can H beam 150 be used for a 6m span?
Yes, but check deflection limits. For heavy loads, consider HEB 150 h beam or larger sections.
3. Is HEA 150 h beam structure the same as H beam 150 steel h beam?
Yes, HEA 150 h shaped beam is a European-standard H beam with 150mm height.
GNEE is an H beam supplier with 18 years of production experience. The h type beam we provide is strictly produced in accordance with standards, has passed quality certification, can provide quality certificates, and accept third-party testing. We are always ready to help you with all your structural h beam needs.