Knowledge

W18x40 Wide-Flange Beam: ASTM A6/A6M Dimensions and A992 Grade 50 Data

May 20, 2025 Leave a message

Reading the W18x40 Designation

In the American system a W shape is a doubly symmetric wide-flange I-beam rolled with parallel flanges. The first number is the nominal depth in inches - W18 shapes are grouped around an 18 inch depth - and the second is the nominal mass in pounds per foot, so W18x40 weighs 40 lb/ft, about 59.5 kg/m. Nominal dimensions, mass and tolerances for rolled W shapes are controlled by ASTM A6/A6M, the general requirements standard for rolled structural steel bars, plates, shapes and sheet piling. Actual delivered depth and flange width differ slightly from the nominal figures, and A6/A6M permits those variations.

Nominal Dimensions and Section Properties

Property US units Metric
Depth d 17.9 in 454.7 mm
Flange width bf 6.02 in 152.9 mm
Flange thickness tf 0.525 in 13.3 mm
Web thickness tw 0.315 in 8.0 mm
Fillet radius r 0.402 in 10.2 mm
Section area A 11.8 in2 76.1 cm2
Moment of inertia Ix 612 in4 25 470 cm4
Elastic section modulus Sx 68.4 in3 1 121 cm3
Moment of inertia Iy 19.1 in4 795 cm4
Plastic modulus Zx 78.4 in3 1 285 cm3
Mass 40 lb/ft 59.5 kg/m

The ratio between strong-axis and weak-axis stiffness is roughly thirty to one, which is typical of a W shape of this size. Bending about the strong axis is efficient; about the weak axis the section is very slender, and unbraced lengths must be controlled by the restraint layout rather than by the section alone.

Material Grades for W Shapes

ASTM A992 Grade 50 is the default grade for W shapes in building frames. It requires a minimum yield strength of 345 MPa (50 ksi), a tensile strength of at least 450 MPa (65 ksi), a maximum yield strength of 450 MPa and a maximum yield-to-tensile ratio of 0.85, which keeps the section ductile enough for plastic design. ASTM A572 Grade 50 is an accepted alternative with the same 345 MPa minimum yield and 450 MPa minimum tensile strength. ASTM A36 remains available, with a 250 MPa minimum yield strength and 400-550 MPa tensile strength, where a lower strength grade is sufficient. Chemistry, tensile and Charpy requirements, when specified, are verified against the product standard and reported on the mill certificate.

Design and Detailing Notes

Two checks usually govern this section: lateral-torsional buckling of the unbraced length and deflection under service load. Because A992 develops a high yield strength, serviceability often controls before strength in floor beams, and increasing the grade does not improve stiffness at all. Web thickness of 8.0 mm is modest for its depth, so concentrated loads from heavy machinery or long-span purlins call for web stiffeners or a bearing check at the load point. Bolt holes and copes are normally sized to the connection standard in use, and the flange width of about 153 mm limits the number of bolts that can be placed across a flange in a single line.

Corrosion Protection and Handling

Uncoated W beams are usually protected by a shop primer, with the site coating system specified separately. For exposed or humid service, hot-dip galvanizing to ISO 1461 or a thermal spray zinc-aluminium coating gives substantially longer life than paint alone. Members should be lifted with slings or clamps rather than by chain only, and stored clear of the ground with spacers to avoid pitting before erection. Damaged primer at bolt holes and cut ends should be touched up before the final coating is applied.

Frequently Asked Questions

Q: What does the 40 in W18x40 mean?
A: It is the nominal mass in pounds per foot, equivalent to about 59.5 kg/m. The 18 refers to the nominal depth of the shape family in inches.

Q: What is the minimum yield strength of a W18x40 in A992?
A: ASTM A992 Grade 50 specifies a minimum yield strength of 345 MPa (50 ksi) and a minimum tensile strength of 450 MPa (65 ksi), with yield strength capped at 450 MPa and a maximum yield-to-tensile ratio of 0.85.

Q: Which standard controls W18x40 dimensions?
A: ASTM A6/A6M, the general requirements standard for rolled structural steel products, defines nominal dimensions, mass and permissible tolerances for W shapes such as W18x40.

Q: Can W18x40 be supplied hot-dip galvanized?
A: Yes. Galvanizing to ISO 1461 is common for exposed steelwork. The steel thickness places the section in a coating band with a specified minimum average thickness, and drainage of the zinc bath must be planned around the fillets and copes.

Q: Is A36 a substitute for A992 in this section?
A: It is permitted where the design was based on A36 properties, but A36 has a lower minimum yield strength of 250 MPa. Substituting A36 for A992 reduces capacity and requires recalculation.

Send Inquiry