Knowledge

HEM 500 and HEM 600 Hot-Rolled H-Beams

May 15, 2025 Leave a message

HEM 500 and HEM 600 are the largest members of the European HEM series of hot-rolled wide-flange H-beams, where M indicates the heavy-flange family with the thickest web and flange for a given depth. These sections are used for extremely heavy loads in columns, main beams, and crane runway structures, where their high axial and bending capacity and high torsional stiffness are essential.

What Are HEM 500 and HEM 600?

The HEM series (also written HE-M) is the heaviest of the three European wide-flange families: HEA (light), HEB (medium), and HEM (heavy). HEM 500 has a nominal depth of 500 mm and HEM 600 a nominal depth of 600 mm, with very thick webs and flanges to carry heavy loads. The beams are hot rolled as complete sections, and typical section weights are about 270 kg/m for HEM 500 and 285 kg/m for HEM 600.

Dimensions and Tolerances

Typical nominal dimensions are:

Parameter HEM 500 HEM 600
Height (h) 524 mm 620 mm
Flange width (b) 306 mm 305 mm
Web thickness (tw) 21 mm 21 mm
Flange thickness (tf) 40 mm 40 mm
Approximate weight 270 kg/m 285 kg/m

Dimensional tolerances follow EN 10034, with typical limits such as straightness of no more than about 1.2 mm per metre and section height deviation of about plus or minus 2 mm. The exact values are verified against the standard for each delivery.

Material Grades and Standards

Material: structural grades such as S355JR and S355J2 per EN 10025-2, where S355J2 guarantees Charpy impact energy at -20 deg C for low-temperature applications.

Dimensional and tolerance standard: EN 10034 for hot-rolled structural steel I and H sections.

Corrosion protection: hot-dip galvanizing per EN ISO 1461 for atmospheric exposure, or specialized systems for marine and chemical environments.

Bolting: high-strength bolt systems per EN 14399 for structural connections.

Section performance highlights:

Very high axial and bending capacity: the heavy flanges and web make HEM 500 and HEM 600 suitable for columns and beams carrying the largest loads in a structure.

High torsional stiffness: the compact, thick-walled section resists torsion far better than lighter sections, which is valuable for eccentrically loaded members.

Heavy-load detailing: a 21 mm web with 40 mm flanges meets the requirements of severe load conditions, and the wide flange improves stress transfer at connections.

Typical Applications

Port machinery: trolley walking beams and main beams of container gantry cranes, where heavy dynamic loads are applied repeatedly.

Heavy industrial plants: long-span trusses in large workshops, and crane runway beams for heavy overhead cranes in foundries and stamping plants.

Energy infrastructure: heavy support columns in power and process plants, and dome frame members for large storage tanks.

High-rise and special structures: heavily loaded columns and transfer members where section strength, not weight, governs.

Fabrication and Protection

Welding: the thick flanges and web require preheating for welding, typically about 100 deg C for plate thicknesses over 25 mm, and qualified welding procedures.

Connections: bolted connections with high-strength bolt assemblies per EN 14399 are commonly used, especially where field assembly is required.

Anti-corrosion solutions by environment: hot-dip galvanizing for conventional atmospheres, epoxy zinc-rich primer systems with a fluorocarbon topcoat for marine corrosion, and thermal-sprayed aluminum with a sealing coat for chemical environments.

Frequently Asked Questions

What do HEM 500 and HEM 600 mean? HEM is the heavy-flange family of European wide-flange sections, and 500 and 600 are the nominal depths in millimetres.

What are the dimensions of HEM 500 and HEM 600? HEM 500 is approximately 524 x 306 mm with a 21 mm web and 40 mm flange, and HEM 600 is approximately 620 x 305 mm with the same 21 mm web and 40 mm flange.

What steel grades are available for HEM beams? Structural grades per EN 10025-2 such as S355JR and S355J2 are common, with S355J2 guaranteeing -20 deg C impact toughness for low-temperature applications.

Can HEM beams be welded? Yes, with qualified welding procedures. The thick flanges and web require preheating, typically around 100 deg C for thicknesses over 25 mm.

What is the difference between HEA, HEB, and HEM? HEA is the light flange series, HEB the medium series, and HEM the heavy series, with progressively thicker webs and flanges for the same nominal depth and increasing load capacity.

What are HEM 500 and HEM 600 used for? They are used for crane runway beams, heavy columns and trusses in industrial plants, port machinery components, and other extremely heavy load-bearing applications.

Send Inquiry