The splicing joint of H-shaped frame column should adopt bolt and welded joint or welded joint.
When bolts and welded joint joints are used, the web should be bolted, and the flange should be connected with a single V-shaped groove of the plate and a full penetration weld of the backing plate.

When the all-welded joint is used, the flange should adopt the single V-shaped groove of the plate and the full penetration weld of the backing plate, and the web should adopt the double-sided partial penetration weld of the K-shaped groove, and the back side is not clear. Design requirements when the web is fully welded, if the thickness of the web is not more than 20mm, it is appropriate to use single V-shaped groove and plate welding. If the thickness of the web is more than 20mm, it is appropriate to use K-shaped groove, and weld after cleaning the root on both sides.

Technical measures for strengthening steel structure
When the steel structure is also damaged, we must immediately find and solve the problem, the main factors of steel structure damage are:
1) The structural bearing capacity is insufficient due to load changes, overdue service, and changes in norms and regulations;
2) Components due to various accidents caused by deformation, distortion, disability, depression, etc., resulting in the weakening of component section, rod warping, connection cracking, etc.;
3) Deformation, cracking and warping of components or connections under the action of temperature difference;
4) Corrosion due to the erosion of chemical substances and electrochemical corrosion resulting in the weakening of the cross-section of steel structure members;
5) Others include mistakes in design, production and construction, and illegal use and operation during the service period.